Constant climate chamber with ICH
In stock
Reconfirm the price with seller
- Customer pickup,
- Courier
- In detail
Description
Advantages:
* Long-term stable test conditions
* Independent of the water supply
* one-stop solution: Temperature/ humidity/ light simulation in one chamber
Performances Characteristics
# Electronically controlled APT.line™ preheating chamber and refrigerating system assuring temperature accuracy and reproducible results
# 2 variable positioned illumination cassettes with BINDER Q1B Synergy Light™ for unique homogenous light distribution
# Temperature range 0 ° C to 70 ° C ( without illumination and humidity)
# Temperature range 10 ° C to 60 ° C ( with illumination and humidity)
# Humidity range 10 % to 75 % RH ( with illumination)
# Humidity range 10 % to 80 % RH ( without illumination)
# MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments
* User friendly LCD screen
* Easy-to-read menu guide
* Integrated electronic chart recorder
* Variety of options for the graphic display of process parameters
* Real time clock
# Electronically controlled humidification and dehumidification system with capacitive humidity sensor suitable for stability tests according to ICH guideline Q1A ( R2)
# Inner glass door with sealing
# Independent adjustable temperature safety device class 3.1 ( DIN 12880) , with visual and audible temperature alarm
# Access port with silicone plug Ø 30 mm, left side
# Safety connection kit for water supply and drainage, including water hose, total length 6 m
# Ethernet interface for APT-COM™ DataControlSystem software
# 2 stainless steel racks
Specification :
Interior dimensions
Width ( mm) 650
Height ( mm) 785
Depth ( mm) 485
Interior volume ( l) 247
Racks ( number standard/ max.) 2 / 7
Load per rack ( kg) 30
Permitted total load ( kg) 100
Weight ( empty) ( kg) 213
Temperature data ( without humidity)
without illumination cassettes ( ° C) 0 - 70
with illumination cassettes, with illumination ( ° C) 10 - 60
Max. heat compensation up to 40 ° C with illumination ( W) 400
Climate data ( with humidity)
Temperature range without illumination cassettes ( ° C) 10 - 70
Temperature range with illumination cassettes with illumination ( ° C) 10 - 60
Temperature variation with illumination
at 25 ° C and 60 % RH ( ± K) 0, 6
at 40 ° C and 75 % RH ( ± K) 0, 6
Temperature fluctuation with illumination
at 25 ° C and 60 % RH ( ± K) 0, 2
at 40 ° C and 75 % RH ( ± K) 0, 2
Humidity range without illumination cassettes ( % RH) 10 - 80
Humidity range with illumination cassettes, with illumination ( % RH) 10 - 75
Humidity fluctuation with illumination
at 25 ° C and 60 % RH ( ± % RH) 1, 5
at 40 ° C and 75 % RH ( ± % RH) 2
Recovery time after doors were open for 30 sec.
at 25 ° C and 60 % RH with illumination ( min.) 3
at 40 ° C and 75 % RH with illumination ( min.) 4
Illumination data per light cassette
ICH-compliant illumination device for photostability testing ( Lux) / ( UVA W/ m² ) 7500 / 1, 4
* Long-term stable test conditions
* Independent of the water supply
* one-stop solution: Temperature/ humidity/ light simulation in one chamber
Performances Characteristics
# Electronically controlled APT.line™ preheating chamber and refrigerating system assuring temperature accuracy and reproducible results
# 2 variable positioned illumination cassettes with BINDER Q1B Synergy Light™ for unique homogenous light distribution
# Temperature range 0 ° C to 70 ° C ( without illumination and humidity)
# Temperature range 10 ° C to 60 ° C ( with illumination and humidity)
# Humidity range 10 % to 75 % RH ( with illumination)
# Humidity range 10 % to 80 % RH ( without illumination)
# MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments
* User friendly LCD screen
* Easy-to-read menu guide
* Integrated electronic chart recorder
* Variety of options for the graphic display of process parameters
* Real time clock
# Electronically controlled humidification and dehumidification system with capacitive humidity sensor suitable for stability tests according to ICH guideline Q1A ( R2)
# Inner glass door with sealing
# Independent adjustable temperature safety device class 3.1 ( DIN 12880) , with visual and audible temperature alarm
# Access port with silicone plug Ø 30 mm, left side
# Safety connection kit for water supply and drainage, including water hose, total length 6 m
# Ethernet interface for APT-COM™ DataControlSystem software
# 2 stainless steel racks
Specification :
Interior dimensions
Width ( mm) 650
Height ( mm) 785
Depth ( mm) 485
Interior volume ( l) 247
Racks ( number standard/ max.) 2 / 7
Load per rack ( kg) 30
Permitted total load ( kg) 100
Weight ( empty) ( kg) 213
Temperature data ( without humidity)
without illumination cassettes ( ° C) 0 - 70
with illumination cassettes, with illumination ( ° C) 10 - 60
Max. heat compensation up to 40 ° C with illumination ( W) 400
Climate data ( with humidity)
Temperature range without illumination cassettes ( ° C) 10 - 70
Temperature range with illumination cassettes with illumination ( ° C) 10 - 60
Temperature variation with illumination
at 25 ° C and 60 % RH ( ± K) 0, 6
at 40 ° C and 75 % RH ( ± K) 0, 6
Temperature fluctuation with illumination
at 25 ° C and 60 % RH ( ± K) 0, 2
at 40 ° C and 75 % RH ( ± K) 0, 2
Humidity range without illumination cassettes ( % RH) 10 - 80
Humidity range with illumination cassettes, with illumination ( % RH) 10 - 75
Humidity fluctuation with illumination
at 25 ° C and 60 % RH ( ± % RH) 1, 5
at 40 ° C and 75 % RH ( ± % RH) 2
Recovery time after doors were open for 30 sec.
at 25 ° C and 60 % RH with illumination ( min.) 3
at 40 ° C and 75 % RH with illumination ( min.) 4
Illumination data per light cassette
ICH-compliant illumination device for photostability testing ( Lux) / ( UVA W/ m² ) 7500 / 1, 4